Single 9000 kVA Silicon-manganese Submerged Arc Furnace

RETURN LIST

PRODUCT DETAIL

9000kVA Submerged Arc Furnace

1. Technical Parameter

  Rated furnace transformer capacity 9000KVA+20% overload

  Primary voltage 20kV

  Transformer tap changer Onload (China make)

  Secondary voltage 104-132V

  Rated secondary current 43.6kA

  Contact element type Forged red copper

  Diameter of electrode Φ950mm

  Electrode type Self baked

  Electrode pitch circle Φ2600mm

  Electrode holder Hydraulic type

  Electrode traveling stroke 1000mm (working)

1500mm (maintenance)

  Electrode traveling speed 0.6 m/min. (up)

0.4 m/min. (down)

  Diameter of furnace shell Φ7000mm

  Height of furnace shell 4200 mm

  Diameter of furnace hearth Φ5800mm

Depth of furnace hearth 2200mm

  Tapping hole number 2 nos.

  Cooling water flow rate 240 tons per hour

  Cooling water working pressure 0.3MPa

  Hydraulic power pack working pressure 8MPa

  Hydraulic medium Mineral oil

 

a) Installation and installation material, furnace refractory lining, hydraulic medium, lubrication medium and cleaning medium;

b) Furnace foundation (Seller provides furnace foundation condition drawings and civil work requirements), embedded furnace foundation parts;

c) Water supply and gas supply main inlet are laid to Seller’s equipment connection point, H.V. incoming line is connected to seller’s H.V. switchboard and Transformer terminals, L.V. supply lines are connect to Seller’s L.V. power distribution panel.